1-8
Enabling the System to Test Connected Cable
You can enable the system to test the cable connected to a specific port. The test result will be returned
in five seconds. The system can test these attributes of the cable: Receive and transmit directions (RX
and TX), short circuit/open circuit or not, the length of the faulty cable.
Table 1-8 Enable the system to test connected cables
Operation Command Remarks
Enter system view
system-view
Enter Ethernet port view
interface
interface-type interface-number
Enable the system to test
connected cables
virtual-cable-test
Required
z Currently, the device is only capable of testing the cable status and cable length. For the testing
items that are currently not supported, “-” is displayed in the corresponding output fields.
z Cable test cannot be performed on an optical port.
Configuring the Interval to Perform Statistical Analysis on Port Traffic
By performing the following configuration, you can set the interval to perform statistical analysis on the
traffic of a port.
When you use the display interface interface-type interface-number command to display the
information of a port, the system performs statistical analysis on the traffic flow passing through the port
during the specified interval and displays the average rates in the interval. For example, if you set this
interval to 100 seconds, the displayed information is as follows:
Last 100 seconds input: 0 packets/sec 0 bytes/sec
Last 100 seconds output: 0 packets/sec 0 bytes/sec
Table 1-9 Set the interval to perform statistical analysis on port traffic
Operation Command Description
Enter system view
system-view
Enter Ethernet port view
interface
interface-type
interface-number
Set the interval to perform
statistical analysis on port traffic
flow-interval
interval
Optional
By default, this interval is 300
seconds.
Disabling Up/Down Log Output on a Port
An Ethernet port has two physical link statuses: UP and Down. When the physical link status of an
Ethernet port changes, the switch will send log to the log server, which in turn acts accordingly. If the

Table of Contents

Other manuals for H3C S3100 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the H3C S3100 Series and is the answer not in the manual?

H3C S3100 Series Specifications

General IconGeneral
BrandH3C
ModelS3100 Series
CategorySwitch
LanguageEnglish

Related product manuals