1-28
You can determine whether or not the link connected to a port is a point-to-point link in one of the
following two ways.
Setting the Link Type of a Port to P2P in system view
Follow these steps to specify whether the link connected to a port is point-to-point link in system view:
To do... Use the command... Remarks
Enter system view
system-view
—
Specify whether the link
connected to a port is
point-to-point link
stp interface interface-list
point-to-point { force-true |
force-false | auto }
Required
The auto keyword is adopted
by default.
Setting the Link Type of a Port to P2P in Ethernet port view
Follow these steps to specify whether the link connected to a port is point-to-point link in Ethernet port
view:
To do... Use the command... Remarks
Enter system view
system-view
—
Enter Ethernet port view
interface interface-type
interface-number
—
Specify whether the link
connected to a port is a
point-to-point link
stp point-to-point { force-true
| force-false | auto }
Required
The auto keyword is adopted
by default.
z If you configure the link connected to a port in an aggregation group as a point-to-point link, the
configuration will be synchronized to the rest ports in the same aggregation group.
z If an auto-negotiating port operates in full duplex mode after negotiation, you can configure the link
of the port as a point-to-point link.
After you configure the link of a port as a point-to-point link, the configuration applies to all the MSTIs the
port belongs to. If the actual physical link of a port is not a point-to-point link and you forcibly configure
the link as a point-to-point link, loops may occur temporarily.
Configuration example
# Configure the link connected to Ethernet 1/0/1 as a point-to-point link.
1) Perform this configuration in system view
<Sysname> system-view
[Sysname] stp interface Ethernet 1/0/1 point-to-point force-true
2) Perform this configuration in Ethernet port view
<Sysname> system-view
[Sysname] interface Ethernet 1/0/1
[Sysname-Ethernet1/0/1] stp point-to-point force-true

Table of Contents

Other manuals for H3C S3100 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the H3C S3100 Series and is the answer not in the manual?

H3C S3100 Series Specifications

General IconGeneral
BrandH3C
ModelS3100 Series
CategorySwitch
LanguageEnglish

Related product manuals