1-13
To do… Use the command… Remarks
Configure advantage factor for a
jitter voice test
adv-factor
adv-number
By default, the advantage factor is
zero.
Start the test
test-enable
Required
Display test results
display hwping results
[ admin-name
operation-tag ]
Required
You can execute the command in
any view.
6) Configuring SNMP test on HWPing client
Follow these steps to configure SNMP test on HWPing client:
To do… Use the command… Remarks
Enter system view
system-view
—
Enable the HWPing client function
hwping-agent enable
Required
By default, the HWPing client
function is disabled.
Create an HWPing test group and
enter its view
hwping
administrator-name
operation-tag
Required
By default, no test group is
configured.
Configure the test type
test-type
snmpquery
Required
By default, the test type is ICMP.
Configure the destination IP
address
destination-ip
ip-address
Required
By default, no destination address
is configured.
Configure the source IP address
source-ip
ip-address
Optional
By default, no source IP address is
configured.
Configure the source port
source-port
port-number
Optional
By default, no source port is
configured.
Configure the number of probes
per test
count
times
Optional
By default, each test makes one
probe.
Configure a test description
description
string
Optional
By default, no description
information is configured.
Configure the maximum number of
history records that can be saved
history-records
number
Optional
By default, the maximum number is
50.
Enable history record
history-record enable
Optional
By default, history record is not
enabled.
Configure the retaining time of
history record
history keep-time
keep-time
Optional
By default, the retaining time of
history record is 120 minutes.
Configure statistics interval and the
maximum number of retained
statistics information
statistics
{
interval
interval |
max-group
number }
Optional
By default, statistics interval is 120
minutes and up to two pieces of
statistics information can be
retained.

Table of Contents

Other manuals for H3C S3100 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the H3C S3100 Series and is the answer not in the manual?

H3C S3100 Series Specifications

General IconGeneral
BrandH3C
ModelS3100 Series
CategorySwitch
LanguageEnglish

Related product manuals