1-27
<Sysname> system-view
[Sysname] hwping-server enable
[Sysname] hwping-server udpecho 10.2.2.2 9000
z Configure HWPing Client (Switch A):
# Enable the HWPing client.
<Sysname> system-view
[Sysname] hwping-agent enable
# Create an HWPing test group, setting the administrator name to administrator and test tag to Jitter.
[Sysname] hwping administrator Jitter
# Configure the test type as jitter
[Sysname-hwping-administrator-Jitter] test-type Jitter
# Configure the IP address of the HWPing server as 10.2.2.2.
[Sysname-hwping-administrator-Jitter] destination-ip 10.2.2.2
# Configure the destination port on the HWPing server.
[Sysname-hwping-administrator-Jitter] destination-port 9000
# Configure to make 10 probes per test.
[Sysname-hwping-administrator-http] count 10
# Set the probe timeout time to 30 seconds.
[Sysname-hwping-administrator-Jitter] timeout 30
# Enable the saving of history records and set the maximum number of history records that can be
saved to 10.
[Sysname-hwping-administrator-Jitter] history-record enable
[Sysname-hwping-administrator-Jitter] history-records 10
# Start the test.
[Sysname-hwping-administrator-Jitter] test-enable
# Display test results
[Sysname-hwping-administrator-Jitter] display hwping results administrator Jitter
HWPing entry(admin administrator, tag Jitter) test result:
Destination ip address:10.2.2.2
Send operation times: 100 Receive response times: 100
Min/Max/Average Round Trip Time: 9/21/13
Square-Sum of Round Trip Time: 18623
Last complete test time: 2000-4-2 8:14:58.2
Extend result:
SD Maximal delay: 10 DS Maximal delay: 10
Packet lost in test: 0%
Disconnect operation number: 0 Operation timeout number: 0
System busy operation number: 0 Connection fail number: 0
Operation sequence errors: 0 Drop operation number: 0
Other operation errors: 0
Jitter result:
RTT Number:100
Min Positive SD:1 Min Positive DS:1
Max Positive SD:6 Max Positive DS:8
Positive SD Number:38 Positive DS Number:25
Positive SD Sum:85 Positive DS Sum:42
Positive SD average:2 Positive DS average:1
Positive SD Square Sum:267 Positive DS Square Sum:162
Min Negative SD:1 Min Negative DS:1
Max Negative SD:6 Max Negative DS:8

Table of Contents

Other manuals for H3C S3100 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the H3C S3100 Series and is the answer not in the manual?

H3C S3100 Series Specifications

General IconGeneral
BrandH3C
ModelS3100 Series
CategorySwitch
LanguageEnglish

Related product manuals