Technical Manual
October 1, 1995 18-006/081-04 GB
133
E:
Key in the Company nos.
The complete OEM number taken from the Service card number and the Company - number will be
programmed in the reader.
The reader database must be reset the first time the reader is initialized.
The modes or options can be changed later on by answering NO to reset database.
F:
The reader cpu can be soft reset by answering YES to RESET READER? Please do not leave this menu by
the C - key as no changes will then be stored. Leave this menu only by YES or NO.
Default data:
The following default data is available after an initialization of a reader:
S-ART address 00:
Input address 00: Soft type 30 - door contact
Input address 01: Soft type 32 - exit push button
Output address 00: Softtype 99 = 70+71 (Intrusion equation = door forced or held) (only used in mode 3).
Output address 01: Softtype 83 - Electric striking plate
Activating type 2.
Door Timing:
Door release time: 10 sec.
Door open time before warning: 30 sec.
Warning time before Door Held alarm: 10 sec.
Personnel group:
No. 1: WP = 2 (always no PIN-code)
(Guest cards) LF = 0 (no padlock function)
HU = 0 (hold-up code disabled)
AC = 001 (THOR intrusion user no.)
LN = 0 (no log of normal access)
No. 2: WP = 1 (always PIN-code)
LF = 0 (no padlock function)
HU = 0 (hold-up code disabled)
AC = 001 (THOR intrusion user no.)
LN = 0 (no log of normal access)
No. 3: WP = 2 (always no PIN-code)
LF = 0 (no padlock function)
HU = 0 (hold-up code disabled)
AC = 002 (THOR intrusion user no.)
LN = 0 (no log of normal access)
Week time programs:
No. 31: 00:00 - 24:00, FNC = 15 (Log all)
No. 34: 00:00 - 24:00, FNC = 32 (Normal door function)