1.11 Elevator Control.
N.B. This function can only be programmed from the 90T AICS configuration software ver. 2.01 or the
90T AMS management software.
The elevator outputs are used to control to which floor(s) the different personnel groups are allowed to go by an
elevator. This can be done f.ex. from one reader placed inside the elevator.
Example: Personnel group no. 004 = Commercial department, who after having swiped their card in the reader
can press the buttons for f.ex. floor 1,2 and 3.
The maximum number of floors (outputs) is 30 (in the reader software) but using the existing S-ART 90T S102
only one output from each S-ART is used and therefore only
max. 15
floors can be controlled.
To each personnel group (250) a group of floors is programmed. The different groups of floors are created by
the 90T AICS or 90T AMS software and downloaded into the readers. Also the programming of the personnel
groups containing the information about the floor group must be programmed by a PC. Up to 250 different floor
groups can be programmed.