1.2.3 THOR Integration of Access and Intrusion.
When the access reader is integrated in a THOR intruder system it is connected via the RS485 multimaster bus
to the THOR central unit and the reader can in this configuration also work as a normal THOR Intruder remote
keypad.
Depending on the THOR Intrusion configuration the max. number of readers integrated on the THOR
Multimaster bus can be up to 31.
It is possible to connect Readers, Remote Keypads, printer interface etc. to the RS485 Multimaster Bus and the
access readers will be a fully integrated part of the alarm system.
An integrated system can also consist of more sub-level busses but only one intruder central unit can be
installed on each sub-level bus and it is only possible to operate the intruder system from terminals or readers
on the same bus.