4.4.2 Set/unsetting from the Terminal 95T ERC or 90T RKP ERC with external reader
heads.
Unset-procedure:
1.: Read the card in the external reader.
2.: The door will open even if the area is set, but the entry time starts. The buzzer starts in the
Reader keypad 95T ERC during the entry time as all normal remote keypads or readers. The
entry time can then be started either by the door opening or by a PIR detector in the entry zone
covering the entry route.
3.: The 95T ERC keypad will then work as a normal intrusion remote keypad and accept the normal
Intrusion
user codes. The area corresponding to the code will then be unset. As the 90T RKP
ER is placed inside the secured area, it is not possible to have access to the intrusion system
without a card.
Set-procedure:
1.: Enter your Intrusion code.
2.: Press the - key. The exit time starts and the buzzer will sound during the exit time as a normal
remote keypad or reader.
3.: Use the exit push-button to open the door.