Technical Manual
October 1, 1995 18-006/081-04 GB
61
To each floor is reserved one output softtype number, starting from softtype 40 for 1. floor, 41 for 2. floor etc.
until 69 for the 30. floor. Please note that only the first 15 floor outputs can be used today using the S-ART 90T
S102.
An elevator output softtype must be programmed to an output address. This can be done directly on the reader
or from the 90T AICS software.
The duration of the output activation is programmed by the Activation types.
Please note that if the entry of a card should be logged in the event log, a contact indicating that a floor push
button has been used
must
be connected to an S-ART input and programmed with the input softtype 30 (door
contact). If this is not done no entry will be logged in the event log.
The elevator outputs are memorized in the local database. A copy local database will
not
copy these data from
one reader to another. A reader can only be programmed with elevator outputs by the AICS software.