Set-procedure:
When a set attempt is successful without set faults, the reader display will be the same for THOR or non-THOR
intrusion systems. In non-THOR systems it is the input softtype 35 that tells the reader if the set attempt by the
output softtype 75 is successful or not.
If the alarm panel gives a set signal within the 10 seconds, the THOR reader will display SYSTEM SET, DOOR
IS CLOSED. Please note that the door will always be closed before the alarm panel is set, meaning that the set-
procedure can only be made on readers placed outside the secured area.
If the connected alarm system does not give a set signal within 10 seconds after the setting, the THOR reader
will show set fault and it is then necessary to go to the alarm panel to see the set faults.