B34
Register
No.
Function name Function code R/W Monitoring and setting items
Data
resolution
126Fh to
1273h
(Reserved) - - -
1274h
Acceleration time (2)
A092 (high) R/W
1 to 360000 0.01 [sec.]
1275h A092 (low) R/W
1276h
Deceleration time (2)
A093 (high) R/W
1 to 360000 0.01 [sec.]
1277h A093 (low) R/W
1278h
Select method to switch to
Acc2/Dec2 profile
A094 R/W
0 (switching by 2CH terminal), 1 (switching by
setting)
2 (Forward and reverse)
-
1279h
Acc1 to Acc2 frequency
transition point
A095 (high) R/W
0 to 40000(100000) 0.01 [Hz]
127Ah A095 (low) R/W
127Bh
Dec1 to Dec2 frequency
transition point
A096 (high) R/W
0 to 40000(100000) 0.01 [Hz]
127Ch A096 (low) R/W
127Dh
Acceleration curve
selection
A097 R/W
0 (linear), 1 (S curve), 2 (U curve), 3
(inverted-U curve), 4 (EL-S curve)
-
127Eh Deceleration curve setting A098 R/W
0 (linear), 1 (S curve), 2 (U curve), 3
(inverted-U curve), 4 (EL-S curve)
-
127Fh (Reserved) - - - -
1280h (Reserved) - - - -
1281h
[OI] input active range start
frequency
A101 (high) R/W
0 to 40000(100000) 0.01 [Hz]
1282h A101 (low) R/W
1283h
[OI] input active range end
frequency
A102 (high) R/W
0 to 40000(100000) 0.01 [Hz]
1284h A102 (low) R/W
1285h
[OI] input active range start
current
A103 R/W 0 to "[OI]-[L] input active range end current" 1 [%]
1286h
[OI] input active range end
current
A104 R/W
"[OI]-[L] input active range start current" to
100
1 [%]
1287h
[OI] input start frequency
select
A105 R/W 0 (external start frequency), 1 (0 Hz) -
1288h to
12A4h
(Reserved) - - - -
12A5h Acceleration curve constant A131 R/W 1 (smallest swelling) to 10 (largest swelling) -
12A6h
Deceleration curve
constant
A132 R/W 1 (smallest swelling) to 10 (largest swelling) -
12A7h to
12AEh
(Reserved) - - - -
12AFh
Operation-target frequency
selection 1
A141 R/W
0 (digital operator), 1 (keypad potentiometer),
2 (input via O), 3 (input via OI), 4 (external
communication), 5 (option ), 7 (pulse train
frequency input)
-

Table of Contents