EasyManua.ls Logo

Honeywell ACUIX - Table 3-2 Typical DIP Switch Settings by Protocol

Honeywell ACUIX
142 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ACUIX™ PTZ High Speed Analog Dome Installation and Configuration Guide
Document 800-05662 Rev C 35
06/10
Table 3-2 Typical DIP Switch Settings by Protocol
Protocol Baud and Parity
Description
SW6 - Baud and Parity Settings SW5 - Protocol Settings
1234567812345678
Intellibus™ 38400 baud, no parity OFF
ON ON OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF ON
MAXPRO* 9600 baud, even parity* OFF OFF
ON OFF ON OFF OFF OFF OFF ON OFF OFF OFF OFF OFF ON
VCL - RS485 9600 baud, no parity OFF OFF
ON OFF OFF OFF OFF OFF ON ON OFF OFF OFF OFF OFF ON
VCL UTC 9600 baud, no parity OFF OFF
ON OFF OFF OFF OFF OFF OFF OFF ON OFF OFF OFF OFF ON
Diamond 9600 baud, even parity OFF OFF
ON OFF ON OFF OFF OFF ON OFF OFF OFF OFF OFF OFF ON
Pelco P 4800 baud, no parity
(default for P-type control)
ON ON OFF OFF OFF OFF OFF OFF ON OFF ON OFF OFF OFF OFF ON
Pelco D 2400 baud, no parity
(default for D-type control)
OFF
ON OFF OFF OFF OFF OFF OFF OFF ON ON OFF OFF OFF OFF ON
Pelco P_AD 4800 baud, no parity
default for P-type control
ON ON OFF OFF OFF OFF OFF OFF ON OFF ON OFF ON OFF OFF ON
Pelco D_AD 2400 baud, no parity
default for D-type control
OFF
ON OFF OFF OFF OFF OFF OFF OFF ON ON OFF ON OFF OFF ON
* defaults

Table of Contents

Other manuals for Honeywell ACUIX

Related product manuals