98
Configuration
Configuring Default Functions: Presets and Tours
Note Remember you access the OSD by pressing 90 Preset.
Task/Action (with Default) Notes
Setting the Default Function Values
1. Select 3 Control Options 5 Set Default Function enter
values into each field as required:
a. From the FUN column, select P, V, or T.
This is the function that performs after being idle for the
specified delay time. The function displays on the screen
as PS=preset, PT=preset tour, or MT= mimic tour.
b. In the NUM column, enter the preset or preset tour number.
• If a preset is reserved for a special function; PS = PS
Reserved displays.
• If preset 1 is entered, but not pre programmed, PS =
Does Not Exist displays.
c. In the DLY column, enter the MIN:SEC (minutes:seconds)
of delay before the function is performed.
The maximum delay is 99 minutes and 59 seconds.
d. In the ENA column, select Y to enable or N to disable the
default function.
If the function is programmed, the text
displays. For example, if P (preset) 1 is
entered pre programmed and named, PS
= Entrance Door displays.
Enabling or Disabling the Default Function
1. Select 3 Control Options 5 Set Default Function
2. Select Enable (Y) or Disable (N) as required.
• IF enabled, and the dome is idle for the programmed DLY
(delay) setting, THEN the dome performs the function
(preset, preset tour, or mimic tour) programmed in the
default function setup menu after the programmed delay
with no activity.
• IF disabled, THEN the unit remains at its present position
until a control command is received.
If contacts are present then the dome
automatically acknowledges the current
contact, resets its delay timer, and
processes the next contact in numerical
order. All contacts are processed before
performing the default function.
If motion detection is enabled, then the
default function is automatically disabled.