ACUIX™ PTZ High Speed Analog Dome Installation and Configuration Guide
Document 800-05662 Rev C 65
06/10
How to Find Home (MAXPRO-mode or Diamond Protocols)
On the controller, press and hold the Fn key, then press F1.
Note For protocols VCL, VCL UTC, Pelco P and Pelco D there is no command to
find home during regular operation.
Step 3: (Optional) Learn about the HJZTP Joystick Controller
The joystick on any controller is used to control the pan and tilt functions. The speed of pan
and tilt is relative to the amount of movement applied to the joystick. The following is a brief
overview of the operation of the HJZTP controller (Diamond, MAXPRO-mode or VCL
protocols available).
For the HJZTP controller:
• the maximum pan speed can be between 120, 240, or 480 per second.
• the maximum tilt speed is one-half the maximum pan speed.
• if the maximum pan speed is set to 240 per second, the maximum tilt speed is set to
120 per second.
Table 4-1 Display Options at Dome Power Up
When the dome first
powers up
If Then
Start up screen text The startup screen msg is
ON
the protocol, baud rate, parity, data bits, camera
model, and firmware release dates and versions
display on the monitor.
The startup screen msg is
OFF
an X displays on the monitor.
Finding home The dome is set to find home
on startup
the message Finding Home... displays on the
monitor followed by Home Found...
If the dome is not set to find
home on startup
it finds home when the first control command is
received at which time the operator can control the