92
Configuration
Task/Action with Default Notes
Programming Contacts
1. Select 3 Control Options 3 Program Alarms 1 Program
Alarms.
2. Locate and select the contact number (for example, 1) to set.
3. In the FUN (function) column, select:
•P = Preset
• V = Preset Tour
• T = Mimic Tour
• N = NightShot Mode
• D = Day mode
4. In the NUM (number) column, enter the applicable preset (P),
preset tour (V) or mimic tour (T) number.
5. In the ENA (enabled) column, select
• Y to enable the contact.
• N to disable.If a contact is disabled, the dome does not
respond to a change of state nor does it perform the
programmed preset, preset tour, or mimic tour.
6. Repeat as required for all contacts.
If preset 1 is entered, but not pre
programmed, PS = Does Not Exist
displays. If a preset is reserved for a
special function; PS = PS Reserved
displays.
When Alarm FUN is set to N or D, the
NUM column has no meaning and control
will automatically go to the ENA column
where you can select Y or N.
Example: Alarm function is set for Night
mode. If the contact is triggered, the
camera goes to Night mode, without
waiting for any acknowledgement.
Setting a Contact Condition
1. Select 3 Control Options 3 Program Alarms 2 Set
Alarm Condition.
2. Locate and select the contact number between 1 and 4 to set
from the Alarm # column.
3. In the Condition column, select OPEN to trigger an contact
when the contact opens or CLOSE to trigger an contact when
the contact closes. See Table 5-3 to help determine how to set
as open or closed.