Smart Array 250
Table 15-105 HPSA_StorageVolumeIndication: Logical Drive status changed to ERROR
Property name Property implementation
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 102
EventTime Time of the event or time of the indication if event time
unknown.
ProviderName HP SmartArray
RecommendedActions Check for failed or removed physical drives.
SystemName Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary Logical drive status error
EventCategory 6 (Primary Storage)
ProbableCause 86 (Disk Failure)
ProbableCauseDescription Logical Drive Status Changed to Error
NetworkAddresses A list of all the IP addresses (IPv4 and IPv6) of the
computer system generating the indication
• 70 (Windows Server 2003 64-bit)
OSType
• 77 (Windows Server 2008 64-bit)
• 103 (Windows Server 2008 R2)
OSVersion Operating system version of the computer system
generating the indication in the format,
major.minor.build
ProviderVersion Provider version generating the information, in the
form: major.minor.revision.build.
SystemFirmwareVersion Firmware version of the computer system generating
the indication
SystemSerialNumber Serial number of the computer system generating the
indication
SystemProductID Product ID of the computer system generating the
indication
SystemModel Model name of the computer system generating the
indication
SystemGUID Platform GUID of the computer system generating the
indication
VariableNames FailureDescription
VariableTypes 1 (String)