Smart Array 259
Table 15-109 HPSA_DeviceIndication: Controller Redundancy state has been set to ACTIVE
Property name Property implementation
ProviderName HP Smart Array
RecommendedActions Check status of all controllers. A controller may have
failed causing this controller to become active.
SystemName Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary Controller redundancy state set to Active
EventCategory 6 (Primary Storage)
ProbableCause 1 (Other)
ProbableCauseDescription Array Controller Redundancy State Changed to Active
NetworkAddresses A list of all the IP addresses (IPv4 and IPv6) of the
computer system generating the indication
70 (Windows Server 2003 64-bit)
OSType
77 (Windows Server 2008 64-bit)
103 (Windows Server 2008 R2)
OSVersion Operating system version of the computer system
generating the indication in the format,
major.minor.build
ProviderVersion Provider version generating the information, in the
form: major.minor.revision.build.
SystemFirmwareVersion Firmware version of the computer system generating
the indication
SystemSerialNumber Serial number of the computer system generating the
indication
SystemProductID Product ID of the computer system generating the
indication
SystemModel Model name of the computer system generating the
indication
SystemGUID Platform GUID of the computer system generating the
indication
VariableNames[0]: FailureDescription
VariableNames
VariableNames[1]: CacheSizeTotal
VariableNames[2]: CacheSerialNumber
VariableTypes[0]: 1 (String)
VariableTypes
VariableTypes[1]: 5 (uint16)
VariableTypes[2]: 1 (String)