Smart Array 274
15.4.17Controller Cache Status – Temporarily Disabled
Table 15-116 HPSA_DeviceIndication: Controller Cache status—Temporarily Disabled
Property name Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at time of indication
PerceivedSeverity 2 (Info)
IndicationTime Time of indication
CIM_AlertIndication
Description A Smart Array controller Cache status has changed to
Temporarily Disabled. This may be caused by a rebuild
or configuration change. Normal operation will return
after background operations have completed.
AlertingMangedElement WBEM path to the HPSA_ArrayController class.
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 10
EventTime Time of the event or time of the indication if event time
unknown.
ProviderName HP Smart Array
RecommendedActions No action is recommended.
SystemName Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary Array controller cache status temporarily disabled
EventCategory 6 (Primary Storage)
ProbableCause 35 (Performance Degraded)
ProbableCauseDescription Array Controller Cache Status Changed to Temporarily
Disabled
NetworkAddresses A list of all the IP addresses (IPv4 and IPv6) of the
computer system generating the indication
• 70 (Windows Server 2003 64-bit)
OSType
• 77 (Windows Server 2008 64-bit)
• 103 (Windows Server 2008 R2)
OSVersion Operating system version of the computer system
generating the indication in the format,
major.minor.build
ProviderVersion Provider version generating the information, in the
form: major.minor.revision.build.