Smart Array  283  
Table 15-120  HPSA_DeviceIndication: Enclosure Power Supply status changed to Redundant Degraded 
Property name  Property implementation 
EventID 303 
EventTime  Time of the event or time of the indication if event time 
unknown. 
ProviderName  HP Smart Array 
RecommendedActions  Check status of all enclosure power supplies. Ensure 
that power supplies have not failed. Add or replace 
power supplies as necessary. 
SystemName  Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating 
the indication 
HP_AlertIndication 
Summary  Power supply status Redundant Degraded 
EventCategory  17 (Primary Storage Power) 
ProbableCause  89 (Power supply failure) 
ProbableCauseDescription  Redundant Power Supply Degraded 
NetworkAddresses  A list of all the IP addresses (IPv4 and IPv6) of the 
computer system generating the indication 
•  70 (Windows Server 2003 64-bit) 
OSType 
•  77 (Windows Server 2008 64-bit) 
•  103 (Windows Server 2008 R2) 
OSVersion  Operating system version of the computer system 
generating the indication in the format, 
major.minor.build 
ProviderVersion  Provider version generating the information, in the 
form: major.minor.revision.build. 
SystemFirmwareVersion Firmware version of the computer system generating 
the indication 
SystemSerialNumber  Serial number of the computer system generating the 
indication 
SystemProductID  Product ID of the computer system generating the 
indication 
SystemModel  Model name of the computer system generating the 
indication 
SystemGUID  Platform GUID of the computer system generating the 
indication 
VariableNames FailureDescription 
VariableTypes 1 (String)