SCSI HBA  453  
Table 18-77  HPSCSI_DeviceIndication: Temperature sensor status change Warning Condition 
Property name  Property implementation 
HWSerialNumber  Enclosure Serial Number 
HP_DeviceIndication 
DeviceModel  Enclosure Model string 
 
18.4.17Temerature Sensor Status Change – Critical 
Note: This indication might not be generated because the SCSI firmware does not report this 
indication. 
Table 18-78 
 HPSCSI_DeviceIndication: Temperature sensor status change—Critical 
Property name  Property implementation 
CIM_Indication 
IndicationIdentifier GUID string generated at indication 
PerceivedSeverity 6 (Critical) 
IndicationTime  Time of indication 
CIM_AlertIndication 
Description  A Storage Enclosure Temperature sensor status has 
changed to Critical. An enclosure temperature is 
reaching the maximum allowed temperature for normal 
operation. A shutdown is imminent. Action is required 
before loss of data occurs. 
AlertingMangedElement  WBEM path of the HPSCSI_StorageEnclosureProcessor 
class instance 
AlertingElementFormat 2 (CIMObjectPath) 
AlertType  5 (Device Alert) 
EventID 309 
EventTime  Time of the event or time of the indication if event time 
unknown. 
ProviderName HP SCSI 
RecommendedActions  Ensure that the system is adequately ventilated. Check 
for proper room temperature and internal/external 
airflow. Add or repair fans and air baffling if 
necessary. 
SystemName  Name of the computer system generating the indication