# Configure the administrator switch.
[Administrator-1] ntdp enable
[Administrator-1] ntdp timer 10
[Administrator-1] ntdp hop 3
[Administrator-1] interface gigabitethernet 0/0/1
[Administrator-1-GigabitEthernet0/0/1] ntdp enable
[Administrator-1-GigabitEthernet0/0/1] quit
[Administrator-1] interface gigabitethernet 0/0/2
[Administrator-1-GigabitEthernet0/0/2] ntdp enable
[Administrator-1-GigabitEthernet0/0/2] quit
# Configure member switch 1.
[Member-1] ntdp enable
[Member-1] ntdp timer 10
[Member-1] ntdp hop 3
[Member-1] interface gigabitethernet 0/0/1
[Member-1-GigabitEthernet0/0/1] ntdp enable
[Member-1-GigabitEthernet0/0/1] quit
[Member-1] interface gigabitethernet 0/0/2
[Member-1-GigabitEthernet0/0/2] ntdp enable
[Member-1-GigabitEthernet0/0/2] quit
# Configure member switch 2.
[Member-2] ntdp enable
[Member-2] ntdp timer 10
[Member-2] ntdp hop 3
[Member-2] interface gigabitethernet 0/0/1
[Member-2-GigabitEthernet0/0/1] ntdp enable
[Member-2-GigabitEthernet0/0/1] quit
# Configure member switch 3.
[Member-3] ntdp enable
[Member-3] ntdp timer 10
[Member-3] ntdp hop 3
[Member-3] interface gigabitethernet 0/0/1
[Member-3-GigabitEthernet0/0/1] ntdp enable
[Member-3-GigabitEthernet0/0/1] quit
After the previous configuration, globally check the NTDP configuration on the administrator
switch. You can find that the interval and range for NTDP to collect topologies is 10 minutes
and 3 hops respectively.
[Administrator-1] display ntdp
Network topology discovery protocol is enabled
Hops : 3
Timer : 10 min
Hop Delay : 200 ms
Port Delay: 20 ms
Total time for last collection:0 ms
Step 4 Enable the cluster function and set the management VLAN.
# Configure the administrator switch.
[Administrator-1] cluster enable
[Administrator-1] cluster
[Administrator-1-cluster] mngvlanid 10
[Administrator-1-cluster] quit
# Configure member switch 1.
[Member-1] cluster enable
[Member-1] cluster
[Member-1-cluster] mngvlanid 10
[Member-1-cluster] quit
Quidway S5700 Series Ethernet Switches
Configuration Guide - Network Management 3 HGMP Configuration
Issue 01 (2011-10-26) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
113

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Huawei Quidway S5700 Series and is the answer not in the manual?

Huawei Quidway S5700 Series Specifications

General IconGeneral
CategorySwitch
Operating Temperature0°C to 45°C
Relative Humidity5% to 95% (non-condensing)
SeriesQuidway S5700
Forwarding PerformanceUp to 96 Mpps
Ports24 or 48 x 10/100/1000Base-T ports
Power SupplyAC or DC
Storage Temperature-40°C to 70°C
Fixed GE Ports24 or 48
Uplink Ports4 x GE SFP ports
Routing ProtocolsRIP, OSPF, BGP
ManagementSNMP, RMON, CLI, Web
VLAN4094 VLANs
PoEOptional