EasyManuals Logo

Huawei Quidway S5700 Series User Manual

Huawei Quidway S5700 Series
415 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #183 background imageLoading...
Page #183 background image
Interface: GigabitEthernet0/0/2
Status: Enabled, Packets Sent: 6, Packets Received: 16, Packets Error: 0
Neighbor 1: Aging Time: 5(s)
MAC Address : 0003-0003-0003
Port Name : GigabitEthernet0/0/1
Software Version: Version 5.70 V200R006C00
Device Name : Member-2
Port Duplex : FULL
Product Ver : S5700
Step 3 Configure NTDP.
# On devices, enable NTDP in the system view and on the interface and configure the interval
and range for NTDP to collect topologies to 10 minutes and 3 hops respectively.
# Configure the administrator switch.
[Administrator-1] ntdp enable
[Administrator-1] ntdp timer 10
[Administrator-1] ntdp hop 3
[Administrator-1] interface gigabitethernet 0/0/1
[Administrator-1-GigabitEthernet0/0/1] ntdp enable
[Administrator-1-GigabitEthernet0/0/1] quit
[Administrator-1] interface gigabitethernet 0/0/2
[Administrator-1-GigabitEthernet0/0/2] ntdp enable
[Administrator-1-GigabitEthernet0/0/2] quit
# Configure member switch 1.
[Member-1] ntdp enable
[Member-1] ntdp timer 10
[Member-1] ntdp hop 3
[Member-1] interface gigabitethernet 0/0/1
[Member-1-GigabitEthernet0/0/1] ntdp enable
[Member-1-GigabitEthernet0/0/1] quit
[Member-1] interface gigabitethernet 0/0/2
[Member-1-GigabitEthernet0/0/2] ntdp enable
[Member-1-GigabitEthernet0/0/2] quit
# Configure member switch 2.
[Member-2] ntdp enable
[Member-2] ntdp timer 10
[Member-2] ntdp hop 3
[Member-2] interface gigabitethernet 0/0/1
[Member-2-GigabitEthernet0/0/1] ntdp enable
[Member-2-GigabitEthernet0/0/1] quit
# Configure member switch 3.
[Member-3] ntdp enable
[Member-3] ntdp timer 10
[Member-3] ntdp hop 3
[Member-3] interface gigabitethernet 0/0/1
[Member-3-GigabitEthernet0/0/1] ntdp enable
[Member-3-GigabitEthernet0/0/1] quit
After the previous configuration, globally check the NTDP configuration on the administrator
switch. You can find that the interval and range for NTDP to collect topologies is 10 minutes
and 3 hops respectively.
[Administrator-1] display ntdp
Network topology discovery protocol is enabled
Hops : 3
Timer : 10 min
Hop Delay : 200 ms
Port Delay: 20 ms
Total time for last collection:0 ms
Quidway S5700 Series Ethernet Switches
Configuration Guide - Network Management 3 HGMP Configuration
Issue 01 (2011-10-26) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
172

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Huawei Quidway S5700 Series and is the answer not in the manual?

Huawei Quidway S5700 Series Specifications

General IconGeneral
CategorySwitch
Operating Temperature0°C to 45°C
Relative Humidity5% to 95% (non-condensing)
SeriesQuidway S5700
Forwarding PerformanceUp to 96 Mpps
Ports24 or 48 x 10/100/1000Base-T ports
Power SupplyAC or DC
Storage Temperature-40°C to 70°C
Fixed GE Ports24 or 48
Uplink Ports4 x GE SFP ports
Routing ProtocolsRIP, OSPF, BGP
ManagementSNMP, RMON, CLI, Web
VLAN4094 VLANs
PoEOptional

Related product manuals