SNMP host:3.0.0.1
FTP server:2.0.0.1
SFTP server:2.0.0.2
cluster-member ftp-timeout: 300 sec(default)
Cluster SNMP NAT capability : enabled
Cluster FTP NAT capability : enabled
There are 4 member(s) in the cluster, and 0 of them are down.
Step 10 Synchronize configuration files.
# Run the configuration synchronization command on the administrator switch, and then member
switches synchronize configuration files to the FTP server (2.0.0.1) in NAT mode.
[HUAWEI_0.Administrator-1] cluster
[HUAWEI_0.Administrator-1-cluster] cluster-plug-play ip 2.0.0.1 username hgmp 
password hgmp
[HUAWEI_0.Administrator-1-cluster] increment-config synchronization
Step 11 Verify the configuration.
After the previous configuration, run the display increment-synchronization-result command
on administrator switch to check whether configuration files are synchronized to the FTP server,
and you can view that success is displayed.
[HUAWEi_0.Administrator-1] display increment-synchronization-result
The result of member switchs' synchronization:
------------------------------------------------------------------------------
SN   Device              MacAddress     IpAddress      result
------------------------------------------------------------------------------
1    S5700               0002-0002-0002 10.0.0.2       success
2    S5700               0003-0003-0003 10.0.0.3       success
3    S5700               0004-0004-0004 10.0.0.4       success
On the FTP server, you can view that the names of configuration files are the MAC address of
member switches, which indicates that configuration synchronization is successful.
----End
Configuration Files
l Configuration file of Administrator-1.
#
 sysname Administrator-1
#
 vlan batch 10
#
 cluster enable
 ntdp enable
 ntdp hop 5
 ntdp timer 10
 ndp enable
#
interface Vlanif10
 ip address 1.0.0.1 255.0.0.0
#
interface GigabitEthernet0/0/1
 port link-type trunk
 port trunk allow-pass vlan 10
 ntdp enable
 ndp enable
#
interface GigabitEthernet0/0/2
 port link-type trunk
 port trunk allow-pass vlan 10
 ntdp enable
 ndp enable
#
Quidway S5700 Series Ethernet Switches
Configuration Guide - Network Management 3 HGMP Configuration
Issue 01 (2011-10-26) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
196