EasyManuals Logo

Huawei Quidway S5700 Series User Manual

Huawei Quidway S5700 Series
415 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #21 background imageLoading...
Page #21 background image
l If the NM station and managed device are both Huawei products, the parameter private-
netmanager can be configured to add more information to alarms, such as the alarm type,
alarm sequence number, and alarm sending time. The information will help you locate and
rectify faults more quickly.
l The ext-vb parameter sets extended bound variables for traps sent to the target host. By
default, the traps sent to the target host do not carry extended bound variables.
Step 6 (Optional) Run:
snmp-agent sys-info { contact contact | location location }
The equipment administrator's contact information or location is configured.
This step is needed if the NM station administrator needs to know equipment administrators'
contact information and locations when the NM station manages many devices. This will allow
the NM station administrator to quickly contact the equipment administrators for fault location
and rectification.
To configure both the equipment administrator's contact information and location, you need to
run the command twice to configure them separately.
Step 7 (Optional) Run:
snmp-agent packet max-size byte-count
The maximum size of an SNMP packet that the device can receive or send is set.
By default, the maximum size of an SNMP packet that the device can receive or send is 12000
bytes.
After the maximum size is set, the device will discard any SNMP packet that is larger than the
set size. The allowable maximum size of an SNMP packet for a device depends on the size of a
packet that the NM station can process; otherwise, the NM station cannot process the SNMP
packets sent from the device.
----End
Follow-up Procedure
After the configurations are complete, basic communication can be conducted between the NM
station and managed device.
l Access control allows any NM station that uses the community name to monitor and manage
all the objects on the managed device.
l The managed device sends alarms generated by the modules that are enabled by default to
the NM station.
If finer device management is required, follow directions below to configure a managed device:
l To allow a specified NM station that uses the community name to manage specified objects
on the device, follow the procedure described in Controlling the NM Station's Access to
the Device.
l To allow a specified module on the managed device to report alarms to the NM station,
follow the procedure described in Configuring the Trap Function.
l If the NM station and managed device are both Huawei products, follow the procedure
described in Enabling the SNMP Extended Error Code Function to allow the device to
send more types of error codes. This allows more specific error identification and facilitates
your fault location and rectification.
Quidway S5700 Series Ethernet Switches
Configuration Guide - Network Management 1 SNMP Configuration
Issue 01 (2011-10-26) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
10

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Huawei Quidway S5700 Series and is the answer not in the manual?

Huawei Quidway S5700 Series Specifications

General IconGeneral
CategorySwitch
Operating Temperature0°C to 45°C
Relative Humidity5% to 95% (non-condensing)
SeriesQuidway S5700
Forwarding PerformanceUp to 96 Mpps
Ports24 or 48 x 10/100/1000Base-T ports
Power SupplyAC or DC
Storage Temperature-40°C to 70°C
Fixed GE Ports24 or 48
Uplink Ports4 x GE SFP ports
Routing ProtocolsRIP, OSPF, BGP
ManagementSNMP, RMON, CLI, Web
VLAN4094 VLANs
PoEOptional