7–3
Chapter 7. RibbonMinder
Configuring the RibbonMinder
This section explains how to unlock the PROGRAM MODE, find the
RibbonMinder options, make changes, exit the configuration menu, and lock
the PROGRAM MODE.
Following this section is a procedure for changing the Ribbon Size option of
RibbonMinder.
NOTE: All RibbonMinder options are automatically saved in NVRAM
when selected.
As you perform the following steps, refer to the RibbonMinder menu
diagram shown in Figure 7–1.
Press the ENTER key to reset
ribbon life to 100%.
Disable*
Display
Fault
100 Y
ards*
Press Scroll °
or Scroll
±
to adjust size.
1 through 255 Y
ards
0*
Press Scroll °
or Scroll
±
to adjust.
–99% through 99%
RIBBONMINDER
Ribbon
Action
Ribbon Size
Ribbon
Adjust
New Ribbon XXX%
T
o exit the configuration menus
T
o view options, press:
T
o select an option, press:
*
= Factory Default
and return to READY
, press:
Enter ReturnScroll Scroll
Start
Enter
T
o exit the configuration menus
New Ribbon*
Do Nothing
Fault Action