E–29
Appendix E. Code V, IGP, and IPDS Menus
• Narrow. Postnet bar codes are printed with a narrow width.
NOTE: The printer caches bar codes to improve performance. Therefore, to
change this configuration value, you will need to select the desired
setting, save the value in a custom set, then power the printer off
and then prewar the printer back on.
UPC/EAN Barcode HRI
Determines whether bar code HRI (human readable information) prints with
UPC and EAN bar codes.
• On. The default. The printer always prints HRI with UPC and EAN bar
codes, regardless of the HRI flag contained in the IPDS bar code
application command.
• Data Stream Setting. The printer uses the HRI flag in the IPDS bar
code application command to determine whether or not to print HRI with
UPC and EAN bar codes. See the 6400 IPDS Programmer’s Reference
Manual for more information about IPDS bar code application
commands.
Enhanced Bar Code Mode
The Enhanced Bar Code Mode option interweaves the dots in IPDS bar
codes so that more bar codes can be printed before the printer ribbon must be
replaced.
• Disable. The default. Bar codes are printed in one of the standard
qualities, as determined by the Bar Code Quality option and IPDS
application commands.
• Enable. Bar codes are printed in the enhanced mode.
Only certain bar code types, sizes, an orientations are supported in Enhanced
Bar Code Mode.
• Only bar codes with a unit module width of 0.017 inches are supported
in Enhanced Bar Code Mode.