IDEC SmartRelay functions
4.4 Special functions list - SF
IDEC SmartRelay Manual
218
Parameters SP and Mq
The set-value SP and the value for Mq can be provided by another already-programmed
function. You can use the actual values of the following functions:
Analog comparator (Page 183)(actual value Ax – Ay)
Analog trigger (Page 178) (actual value Ax)
Analog amplifier (Page 191) (actual value Ax)
Analog multiplexer (Page 209) (actual value AQ)
Analog ramp control (Page 212) (actual value AQ)
Analog Math (Page 224) (actual value AQ)
Up/down counter (Page 168) (actual value Cnt)
Analog filter (Page 229) (actual value AQ)
Average value (Page 235) (actual value AQ)
Max/Min (Page 231) (actual value AQ)
On-delay (Page 132) (current time Ta)
Off-delay (Page 136) (current time Ta)
On-/off-delay (Page 138) (current time Ta)
Retentive on-delay (Page 140) (current time Ta)
Interval time-delay relay/Pulse output (Page 142) (current time Ta)
Edge-triggered interval time-delay relay (Page 144) (current time Ta)
Asynchronous pulse generator (Page 146) (current time Ta)
Stairwell light switch (Page 150) (current time Ta)
Dual-function switch (Page 152) (current time Ta)
Stopwatch (Page 166) (actual value AQ)
PI controller (actual value AQ)
Frequency trigger (Page 175) (actual value Fre)
Select the required function by the block number. For information on parameter defaults, refer
to the On-delay (Page 132)topic.
Parameters KC, TI
Please note the following circumstances:
If parameter KC has value 0, the "P" function (proportional control) will not be executed.
If parameter TI has value 99:59 m, the "I" function (integral-action control) will not be
executed.
Parameter p (number of decimals)
Applies only to the PV, SP, Min and Max values displayed in a message text.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

Table of Contents

Other manuals for IDEC SMARTRELAY

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IDEC SMARTRELAY and is the answer not in the manual?

IDEC SMARTRELAY Specifications

General IconGeneral
BrandIDEC
ModelSMARTRELAY
CategoryOther
LanguageEnglish

Related product manuals