Programming IDEC SmartRelay
3.8 Configuring additional functions for IDEC SmartRelay
IDEC SmartRelay Manual
94
3.8 Configuring additional functions for IDEC SmartRelay
After you have successfully created the second circuit program, you can configure additional
functions by means of the following menu commands:
• Network
• Diagnostics
UDF and Data Log
You can configure the UDF and Data Log functions only from WindLGC. After you have
configured them in WindLGC and downloaded them to the IDEC SmartRelay, you can then
edit elements connected to these functions from the device:
• UDFs (User-Defined Functions)
• Data Log
Network digital and analog I/O
You can configure the following connectors representing network digital or analog inputs/
outputs only from WindLGC:
• Network digital inputs
• Network analog inputs
• Network digital outputs
• Network analog outputs
3.8.1 Configuring network settings
An IDEC SmartRelay can establish network communication with other IDEC SmartRelay or a
PC with WindLGC V8.0 (For more detailed information, refer to the Maximum IDEC
SmartRelay network setup (Page 15) topic). You can configure the IDEC SmartRelay network
only from WindLGC V8.0 . From IDEC SmartRelay, you can configure your IDEC
SmartRelay's network settings including IP address, subnet mask and gateway.
Note
If your circuit program in an IDEC SmartRelay contains any network digital or analog inputs/
outputs, you can only edit the "Par" parameter of function blocks from IDEC SmartRelay. You
can not edit any of the rest of the circuit program from the device.
Note
You can configure IDEC SmartRelay's network settings including IP adress, subnet mask
and gateway with the access level of administrator only. With the access level of operator,
you can only view but cannot change the network settings.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

Table of Contents

Other manuals for IDEC SMARTRELAY

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IDEC SMARTRELAY and is the answer not in the manual?

IDEC SMARTRELAY Specifications

General IconGeneral
BrandIDEC
ModelSMARTRELAY
CategoryOther
LanguageEnglish

Related product manuals