115VARIABLE SPEED DRIVE SERIES III LIT-12012999—June 2018 www.johnsoncontrols.com
Chapter 7—Advanced application parameter
Table 173. Setpoint 1 — P7.3.2
Code Parameter Min. Max. Unit Default ID Note
P7.3.2.1

PID1 Set Point 1 Source 1 1312 0 = Not Used
1 = PID1 Keypad Set Point 1
2 = PID1 Keypad Set Point 2
3 = AI1
4 = AI2
5 = Slot A: AI1
6 = Slot B: AI1
7 = FB Process Data Input 1
8 = FB Process Data Input 2
9 = FB Process Data Input 3
10 = FB Process Data Input 4
11 = FB Process Data Input 5
12 = FB Process Data Input 6
13 = FB Process Data Input 7
14 = FB Process Data Input 8
15 = PID2 Output
16 = FB PID1 Set Point 1
17 = FB PID1 Set Point 2
P7.3.2.2
PID1 Set Point 1 Min -200.00 200.00 % 0.00 1313
P7.3.2.3
PID1 Set Point 1 Max -200.00 200.00 % 100.00 1314
P7.3.2.4

PID1 Set Point 1 Sleep Enable 0 1315 See Par ID 1346
P7.3.2.5

PID1 Set Point 1 Sleep Unit Sel 0 2396 0 = Output Frequency
1 = Motor Speed
2 = Motor Current
3 = PID1 Feedback
P7.3.2.6
PID1 Set Point 1 Sleep Level Varies 0.00 2450
P7.3.2.7
PID1 Set Point 1 Sleep Delay 0 3000 s 0 1317
P7.3.2.8
PID1 Set Point 1 Wake
Up Level
-99999.99 99999.99 Varies 0.00 1318
P7.3.2.9
PID1 Set Point 1 Boost -2.0 2.0 1.0 1320
P7.3.2.10
PID1 Set Point 1 Comp Enable 0 1352 See Par ID 1346
P7.3.2.11
PID1 Set Point 1 Comp Max -200.00 200.00 % 0.00 1353
Table 174. Setpoint 2 — P7.3.3
Code Parameter Min. Max. Unit Default ID Note
P7.3.3.1

PID1 Set Point 2 Source 2 1321 See Par ID 1312
P7.3.3.2
PID1 Set Point 2 Min -200.00 200.00 % 0.00 1322
P7.3.3.3
PID1 Set Point 2 Max -200.00 200.00 % 100.00 1323
P7.3.3.4

PID1 Set Point 2 Sleep Enable 0 1324 See Par ID 1346
P7.3.3.5

PID1 Set Point 2 Sleep Unit Sel 0 2397 See Par ID 2396
P7.3.3.6
PID1 Set Point 2 Sleep Level Varies 0.00 2452
P7.3.3.7
PID1 Set Point 2 Sleep Delay 0 3000 s 0 1326
P7.3.3.8
PID1 Set Point 2 Wake Up
Level
-99999.99 99999.99 Varies 0.00 1327
P7.3.3.9
PID1 Set Point 2 Boost -2.0 2.0 1.0 1329
P7.3.3.10
PID1 Set Point 2 Comp Enable 0 1354 See Par ID 1346
P7.3.3.11
PID1 Set Point 2 Comp Max -200.00 200.00 % 0.00 1355
Note:
Parameter value can only be changed after the drive has stopped.
Parameter value will be set to be default when changing macros.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Johnson Controls VS3 Series and is the answer not in the manual?

Johnson Controls VS3 Series Specifications

General IconGeneral
BrandJohnson Controls
ModelVS3 Series
CategoryInverter
LanguageEnglish

Related product manuals