Important safety information
Hazardous high voltage
WARNING
The components of the power unit are live when the
AC drive is connected to mains potential. Coming into
contact with this voltage is extremely dangerous and
may cause death or severe injury.
WARNING
The motor terminals U, V, W and the brake resistor
terminals are live when connected to mains, even if
themotor is not running.
WARNING
After disconnecting the AC drive from the mains,
waituntil the indicators on the keypad go out (if no
keypad is attached see the indicators on the cover).
Wait 5 more minutes before doing any work on
the connections. Do not open the cover before this
time hasexpired. After expiration of this time, use a
measuring equipment to absolutely ensure that no
voltage is present. Always ensure absence of voltage
before starting any electrical work!
WARNING
The control I/O-terminals are isolated from the mains
potential. However, the relay outputs and other I/O-
terminals may have a dangerous control voltage present
even when disconnected from mains.
WARNING
Before connecting the AC drive to mains, confirm that
the front and cable covers of drive are closed.
WARNING
During a ramp stop (see the Application Manual), the
motor is still generating voltage to the drive. Therefore,
do not touch the components of the AC drive before the
motor has completely stopped. Wait until the indicators
on the keypad go out (if no keypad is attached see
the indicators on the cover). Wait additional 5 minutes
before starting any work on the drive.
Important warnings
WARNING
AC drive is meant for fixed installations only.
WARNING
Do not perform any measurements when the AC drive is
connected to the mains.
WARNING
The ground leakage current of AC drives exceeds 3.5
mA AC. According to standard EN61800-5-1, a reinforced
protective ground connection must be ensured.
WARNING
If the AC drive is used as a part of a machine, the machine
manufacturer is responsible for providing the machine
with a supply disconnecting device (EN 60204-1).
WARNING
Only spare parts delivered can be used.
WARNING
At power-up, power brake or fault reset the motor will
start immediately if the start signal is active, unless the
pulse control for Start/Stop logic has been selected.
Furthermore, the I/O functionalistic (including start
inputs) may change if parameters, applications or
software are changed. Disconnect, therefore, the motor
if an unexpected start can cause danger.
WARNING
The motor starts automatically after automatic fault
reset if the auto restart function is activated. See the
Application Manual for more detailed information.
WARNING
Prior to measurements on the motor or the motor cable,
disconnect the motor cable from the AC drive.
WARNING
Do not touch the components on the circuit boards.
Static voltage discharge may damage the components.
WARNING
Check that the EMC level of the AC drive corresponds to
the requirements of your supply network.