122 VARIABLE SPEED DRIVE SERIES III LIT-12012999—June 2018 www.johnsoncontrols.com
Chapter 7—Advanced application parameter
Table 195. Interval 1 — P11.1, continued
Code Parameter Min. Max. Unit Default ID Note
P11.1.4
Interval 1 From Day 0 517 0 = Sunday
1 = Monday
2 = Tuesday
3 = Wednesday
4 = Thursday
5 = Friday
6 = Saturday
P11.1.5
Interval 1 To Day 0 518 See Par ID 517
P11.1.6
Interval 1 Channel 0 519 0 = Not Used
1 = Time Channel 1
2 = Time Channel 2
3 = Time Channel 3
Table 196. Interval 2 — P11.2
Code Parameter Min. Max. Unit Default ID Note
P11.2.1
Interval 2 Setting 0 2488 See Par ID 2487
P11.2.2
Interval 2 On Time 0 495
P11.2.3
Interval 2 Off Time 0 497
P11.2.4
Interval 2 From Day 0 520 See Par ID 517
P11.2.5
Interval 2 To Day 0 521 See Par ID 517
P11.2.6
Interval 2 Channel 0 522 See Par ID 519
Table 197. Interval 3 — P11.3
Code Parameter Min. Max. Unit Default ID Note
P11.3.1
Interval 3 Setting 0 2489 See Par ID 2487
P11.3.2
Interval 3 On Time 0 499
P11.3.3
Interval 3 Off Time 0 501
P11.3.4
Interval 3 From Day 0 523 See Par ID 517
P11.3.5
Interval 3 To Day 0 524 See Par ID 517
P11.3.6
Interval 3 Channel 0 525 See Par ID 519
Table 198. Interval 4 — P11.4
Code Parameter Min. Max. Unit Default ID Note
P11.4.1
Interval 4 Setting 0 2490 See Par ID 2487
P11.4.2
Interval 4 On Time 0 503
P11.4.3
Interval 4 Off Time 0 505
P11.4.4
Interval 4 From Day 0 526 See Par ID 517
P11.4.5
Interval 4 To Day 0 527 See Par ID 517
P11.4.6
Interval 4 Channel 0 528 See Par ID 519
Table 199. Interval 5 — P11.5
Code Parameter Min. Max. Unit Default ID Note
P11.5.1
Interval 5 Setting 0 2491 See Par ID 2487
P11.5.2
Interval 5 On Time 0 507
P11.5.3
Interval 5 Off Time 0 509
P11.5.4
Interval 5 From Day 0 529 See Par ID 517
P11.5.5
Interval 5 To Day 0 530 See Par ID 517
P11.5.6
Interval 5 Channel 0 531 See Par ID 519
Note:
Parameter value can only be changed after the drive has stopped.
Parameter value will be set to be default when changing macros.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Johnson Controls VS3 Series and is the answer not in the manual?

Johnson Controls VS3 Series Specifications

General IconGeneral
BrandJohnson Controls
ModelVS3 Series
CategoryInverter
LanguageEnglish

Related product manuals