Table 32: EX Series Switch Environmental Tolerances (continued)
Environment Tolerance
Switch or
device SeismicTemperatureRelative HumidityAltitude
Complies with Zone 4
earthquake
requirements as per
GR-63, Issue 4.
Normal operation ensured in the
temperature range 32° F ( C)
through 113° F (45° C)
Normal operation ensured in
the relative humidity range
10% through 85%
(noncondensing)
No performance
degradation up to
10,000 feet
(3048 meters)
EX3400
Complies with Zone 4
earthquake
requirements as per
GR-63, Issue 4.
Normal operation ensured in the
temperature range 32° F ( C)
through 113° F (45° C)
Normal operation ensured in
the relative humidity range
10% through 85%
(noncondensing)
No performance
degradation up to
10,000 feet
(3048 meters)
EX4200
Complies with Zone 4
earthquake
requirements as per
GR-63, Issue 4.
Normal operation ensured in the
temperature range 32° F ( C)
through 113° F (45° C)
Normal operation ensured in
the relative humidity range
10% through 85%
(noncondensing)
No performance
degradation up to
10,000 feet
(3048 meters)
EX4300
Complies with Zone 4
earthquake
requirements as per
GR-63, Issue 4.
Normal operation ensured in the
temperature range 32° F ( C)
through 113° F (45° C)
Normal operation ensured in
the relative humidity range
10% through 85%
(noncondensing)
No performance
degradation up to
10,000 feet
(3048 meters)
EX4500
Complies with Zone 4
earthquake
requirements as per
GR-63, Issue 4.
EX4550-32F
switches—Normal operation
ensured in the temperature
range 32° F (0° C) through
113° F (45° C)
EX4550-32T
switches—Normal operation
is ensured in the temperature
range 32° F through 104° F
(40° C)
Normal operation ensured in
the relative humidity range
10% through 85%
(noncondensing)
No performance
degradation up to
10,000 feet
(3048 meters)
EX4550
Designed to comply
with Zone 4
earthquake
requirements per
NEBS GR-63-CORE,
Issue 4.
Normal operation ensured in
the temperature range 32° F
(0° C) through 113° F (45° C)
Nonoperating storage
temperature in shipping
container: –40° F (–40° C)
through 158° F (70° C)
Normal operation ensured in
the relative humidity range
5% through 90%,
noncondensing
Short-term operation
ensured in the relative
humidity range 5%
through 93%,
noncondensing
NOTE: As defined in
NEBS GR-63-CORE,Issue
4, short-term events can
be up to 96 hours in
duration but not more
than 15 days per year.
No performance
degradation to
6,562 feet
(2000 meters)
EX4600
Copyright © 2016, Juniper Networks, Inc.60
EX3200 Switch Hardware Guide

Table of Contents

Other manuals for Juniper EX3200

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Juniper EX3200 and is the answer not in the manual?

Juniper EX3200 Specifications

General IconGeneral
ModelEX3200
Rack Units1U
Layer SupportLayer 2 and Layer 3
Junos OSYes
Maximum VLANs4093
DRAM512 MB
Flash Memory256 MB
Ports24 or 48
Uplink Ports4 SFP
Power SupplyAC or DC
MAC Address Table Size16, 000 entries
Dimensions (W x D x H)17.4 x 14.4 x 1.7 inches
Weight12.3 lb (5.6 kg)
Operating Temperature0°C to 40°C