:BORDer command
:BORDer <name>
:FORMat:BORDer <name> Specify binary byte order
Parameters <name> = NORMal Normal byte order for binary formats
SWAPped Reverse byte order for binary formats
Query :BORDer? Query byte order
Description This command is used to control the byte order for the IEEE754 binary
formats. For normal byte order, the data format for each element is sent as
follows:
Byte 1 Byte 2 Byte 3 Byte 4 (Single precision)
Byte 1 Byte 2 ... Byte 8 (Double precision)
For reverse byte order, the data format for each element is sent as follows:
Byte 4 Byte 3 Byte 2 Byte 1 (Single precision)
Byte 8 Byte 7 ... Byte 1 (Double precision)
The ‘#,0’ Header is not affected by this command. The Header is always sent
at the beginning of the data string for each measurement conversion.
The ASCII data format can only be sent in the normal byte order. The
SWAPped selection is ignored when the ASCII format is selected.
5-30 SCPI Command Reference

Table of Contents

Other manuals for Keithley 2010

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keithley 2010 and is the answer not in the manual?

Keithley 2010 Specifications

General IconGeneral
Frequency Range3 Hz to 300 kHz
DC Voltage Range100 mV to 1000 V
AC Voltage Range100 mV to 750 V
DC Current Range3 A
DC Current Accuracy0.05%
AC Current Range3 A
Resistance Accuracy0.01%
InterfaceGPIB, RS-232
Power Supply50 Hz or 60 Hz

Related product manuals