Kinco FD5P AC series servo
Table 10-30 Interpolation control related parameters
Set the operation mode to interpolation mode
0x1F Enable drive, run interpolation mode
0x06 Loose axis, close drive enable
0x86 Reset drive failure
target absolute/relative position
In interpolation mode, it is set according to the
synchronization message cycle of the master
station
value synchronization period
0
1ms
1
2ms
2
4ms
3
8ms
ECAN Synchronous
Clock Mode
Set to 1 in interpolation mode to enable
clock synchronization, and set to 0 in non-
interpolation mode to disable clock
synchronization.
Monitor the synchronous communication
status in interpolation mode, if the value
keeps changing, it means that there is
communication interference or the
synchronization period is inconsistent with
the master station setting