Chapter 2 Servo system installation
requirements and notes
Kinco FD5P AC series servo driver
manual
—Corrosive gases
Please use the original packaging for storage and transportation, the original packaging provides
sufficient protection to avoid common problems.
Environmental conditions
Table
2-1
Environmental requirements
No sun and rain, no corrosive gas, no flammable gas, no oil and gas, dry and dust-free, and well ventilated
(such as electrical cabinets)
There is no power limit when the altitude is below 1000m. When the working altitude is above 1000m, the power
usage needs to be reduced by 1.5% for every 100m rise.
Under 5.9m/s2 10
〜
60Hz
(
Do not connect at the resonance point
)
Technical requirements
In order to use the product correctly and safely, the following requirements should be always observed:
Operation of the product in accordance with the relevant safety regulations is permitted only if the
connection and environmental conditions specified in the product technical data and the technical
requirements of all other connected components comply with the product specifications.
Please follow the instructions and read warnings in this document carefully.
Operator requirements
This product may only be operated by an electrical engineer familiar with the following regulations:
—Installation and operation of electrical control systems
—Applicable regulations for safe operation of engineering systems
—Applicable regulations for accident prevention and occupational safety
—User manual for the product