Code
Name LCD Display Setting Range
Property*
V/F SL Ref.
27 0h131B Frequency jump
Jump Freq
0:No X/A O I/P p.106
28
19
0h131C
Jump frequency
lower limit1
Jump Lo 1
frequency upper
10.00 O/A O I/P p.106
29
19
0h131D
Jump frequency
upper limit1
Jump Hi 1
lower limit1-
Maximum
15.00 O/A O I/P p.106
30
19
0h131E
Jump frequency
lower limit2
Jump Lo 2
frequency upper
20.00 O/A O I/P
p.106
31
19
0h131F
Jump frequency
upper limit2
Jump Hi 2
lower limit2-
Maximum
25.00 O/A O I/P p.106
32
19
0h1320
Jump frequency
lower limit3
Jump Lo 3
frequency upper
30.00 O/A O I/P p.106
33
19
0h1321
Jump frequency
upper limit3
Jump Hi 3
lower limit3-
Maximum
35.00 O/A O I/P
p.106
41
20
0h1329
current
BR Rls Curr 0.0-180.0(%) 50.0 O/A O I/P p.189
42
20
0h132A
delay time
BR Rls Dly 0.00-10.00(s) 1.00 X/A O I/P p.189
44
20
0h132C
Forward
BR Rls Fwd Fr
0.00-Maximum
frequency(Hz)
1.00 X/A O I/P p.189
45
20
0h132D
Reverse
BR Rls Rev Fr
0.00-Maximum
frequency(Hz)
1.00 X/A O I/P p.189
46
20
0h132E
BR Eng Dly 0.00-10.00(s) 1.00 X/A O I/P p.189
47
20
0h132F
BR Eng Fr
0.00-Maximum
frequency(Hz)
2.00 X/A O I/P p.189
50 0h1332
Energy saving
operation
E-Save Mode
0:None X /A O X
p.166
19
Displayed when Ad. 27 is set to 1 (Yes).
20
Displayed if either OU.31 or OU.33 is set to 35 (BR Control).