Table of Functions
279
Code
Comm.
Address
Name LCD Display Setting Range
Initial
Value
Property
*
V/F SL Ref.
43
33
0h142B
Speed estimator P
gain2
PM SpdEst
Kp 2
0~32000 300 X/A X P
44
33
0h142C
Speed estimator I
gain2
PM SpdEst Ki
2
0~32000 30 X/A X P
45
33
0h142D
Speed estimator
feed forward high
speed rate [%]
PM Flux FF %
0~100[%] 30.0 X/A X P
46
33
0h142E
Initial pole
position detection
options
Init Angle Sel
0
None
1 X/A
P
-
-
1
Angle
2
Align
48
33
-
Current controller
P gain
ACR P Gain 0-10000 1200 O/A X I/P -
49
33
-
Current controller
I gain
ACR I Gain 0-10000 120 O/A X I/P -
50
33
0h1432
Voltage controller
limit
V Con HR
0~100.0[%] 10.0 X/A X P
51
33
0h1433
Voltage controller I
gain
V Con Ki
0~1000.0[%] 10.0 X/A X P
52 0h1434
Torque controller
output filter
Torque Out
LPF
0-2000(ms) 0 X/A X I/P p.150
53 0h1435
Torque limit
setting options
Torque Lmt
Src
0
Keypad-1
0:
Keypad
-1
X/A X I/P p.150
1
Keypad-2
2
V1
4
V2
5
I2
6
Int 485
8
FieldBus
9
UserSeqLin
k
12
Pulse
54
34
0h1436
Positive-direction
reverse
torque limit
FWD
+Trq Lmt
0.0-200.0(%) 180 O/A X I/P p.150
55
34
0h1437
Positive-direction
regeneration
torque limit
FWD
Trq Lmt
0.0-200.0(%) 180 O/A X I/P p.150
34
Displayed when dr.09 is set to 4 (IM Sensorless). This will change the initial value of the
parameter at Ad.74 (Torque limit) to 150%.