EasyManua.ls Logo

LSIS LSLV-S100 - Page 294

LSIS LSLV-S100
411 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
280
Table of Functions
Code
Comm.
Address
Name LCD Display Setting Range
Initial
Value
Property
*
V/F SL Ref.
56
34
0h1438
Negative-
direction
regeneration
torque limit
REV +Trq
Lmt
0.0-200.0(%) 180 O/A X I/P p.150
57
34
0h1439
Negative-
direction reverse
torque limit
REV Trq
Lmt
0.0-200.0(%) 180 O/A X I/P p.150
62
34
0h143E
Speed limit
Setting
Speed Lmt
Src
0
Keypad-1
0:
Keypad
-1
X/A X I/P -
1
Keypad-2
2
V1
4
V2
5
I2
6
Int 485
7
FieldBus
8
UserSeqLin
k
63
34
0h143F
Positive-direction
speed limit
FWD Speed
Lmt
0.00~ Maximum
frequency (Hz)
60.00 O/A X I/P -
64
34
0h1440
Negative-
direction speed
limit
REV Speed
Lmt
0.00~ Maximum
frequency (Hz)
60.00 O/A X I/P -
65
34
0h1441
Speed limit
operation gain
Speed Lmt
Gain
100~5000[%]
500 O/A X I/P -
69
35
PM speed search
current
SS Pulse Curr
15
10~100 O/A X P
70
0h
1446
Speed search
mode selection
SS Mode
0
Flying
Start-1
36
0:
Flying
Start-1
X/A O I/P p.170
1
Flying
Start-2
2
Flying
Start-3
35
71 0h1447
Speed search
operation selection
Speed
Search
bit
0000- 1111
0000
37
X/A O I/P p.170
0001
Selection of
speed
35
Displayed when dr.09 (Control Mode) is set to 6 (PM Sensorless).
36
Will not be displayed if dr.09 is set to 4 (IM Sensorless).
37
The initial value 0000 will be displayed on the keypad as .

Table of Contents

Other manuals for LSIS LSLV-S100

Related product manuals