Rigging work
12.8 Outrigger operation
12 - 48 3 302 690 en Operating manual
GMK4100L-1
23.11.2017
From the
control units
Starting the engine
Start the engine from the driver's cab; à p. 4 - 13.
You can also start the engine from the control units;
à p. 12 - 27.
Switching on the lighting
Only the lamp (1) lights up after opening
the door.
Press any button.
The lights are switched on.
Moving the outrigger beams
H
You can only operate the outrigger beams to the left and right of the control
unit on the operator's side.
Observe the safety instructions for operating the outriggers;
à p. 12 - 47.
Press the button
Additionally press the button for the desired
outrigger beam.
The outrigger beams move until you let go of the respective button or until
the respective end position has been reached.
5 For high-speed mode
6 For normal speed.
1 Extend left
2 Retract left
3 Retract right
4 Extend right
1 + 4 Extend both
2 + 3 Retract both