100 SyncServer 600 Series User’s Guide 098-00720-000 Revision D1 – February, 2018
Chapter 4
Navigation Windows
Disp (ms) Dispersion represents the maximum error of the SyncServer relative to the NTP
association.There are two components in dispersion, those determined by the
peer relative to the primary reference source of standard time and those
measured by the SyncServer relative to the peer. They provide not only precision
measurements of offset and delay, but also definitive maximum error bounds, so
that the SyncServer can determine not only the time, but the quality of the time as
well.
Poll (s) The length of the interval (in seconds) with which the SyncServer polls the
remote server, usually starting at 64 seconds and gradually increasing to 1024
seconds. Valid values range from 16 to 65535, increasing by powers of 2. The
polling interval for the Hardware Clock is fixed at 16 seconds. The
user-configured Minimum and Maximum Poll Interval settings on the NTP -
Config page limit this interval.
Table 4-6. NTPd Associations Parameters (Continued)