172 SyncServer 600 Series User’s Guide 098-00720-000 Revision D1 – February, 2018
Chapter 5
SyncServer S6x0 CLI Command Set
set service
Use this command to enable or disable HTTP on the SyncServer S6x0. When
disabled the Web interface will not be accessible. The only way to re-enable HTTP
is using this CLI command.
Disabling HTTP provides a method to effectively eliminate the ability to remotely
configure SyncServer S6x0.
Command Syntax:
set service http {enable | disable}
Example:
To enable HTTP:
set service http enable