252 SyncServer 600 Series User’s Guide 098-00720-000 Revision D1 – February, 2018
Appendix A System Messages
Message Provisioning
Message Provisioning
The SyncServer S6x0 supports logging of events using syslog defined facility and
severity codes and system defined facility codes as follows:
Facility codes
4 Security/authorization messages
20 SyncServer S6x0 Messages (events and alarms)
21 SyncServer S6x0 Command History
22 SyncServer S6x0 Messages (events and alarms)
Severity codes
2 (critical) Critical: critical conditions
3 (major) Error: error conditions
4 (minor) Warning: warning conditions
5 (event) Notice: normal but significant condition
6 Info: Informational
The syslog message format is as follows:
Mmm dd hh:mm:ss
host_name Process-name AlarmID,Index,Severity, MsgText
Where:
Mmm = Month; dd = date; hh:mm:ss = system time
host_name = hostname
process-name = alarmd
AlarmID = 000 thru Max_AlarmID
Index = 0 thru 155
Notes: Severity codes 2, 3, and 4, are also indicated by the Alarm
LED(s) on the front panel.