098-00720-000 Revision D1 – February, 2018 SyncServer 600 Series User’s Guide 227
Chapter 6 Provisioning
Provisioning Alarms
Table 6-22. Configuring Alarm Settings
Method Steps Notes
Web Interface Admin > Alarms
Configure Alarm
1. Enter the “Auto ACK” value (Auto
Acknowledgement) for the alarm.
2. Use the drop-down box for “Severity” to
set the alarm to “Major”, “Minor”, or
“Notify”.
3. Enter the “Reporting Delay” value (in
seconds) for the alarm.
4. Use the check box for “Send Trap” to
enable/disable an SNMP trap for the
alarm.
5. Use the check box for “Write Log” to
enable/disable recording in the log
when the alarm is triggered.
6. Use the check box for “Send Email” to
enable/disable email notification for the
alarm.
7. Click the Apply button.
Clear Alarm
1. Use the check box for “Clear Now” for
the alarm to be cleared.
2. Click the Apply button.
Auto-Acknowledge
has the has same
effect as a manual
"Clear Now"
(described below). It
just does it
automatically after
the specified number
of seconds. Setting
this value to zero
causes Auto-
Acknowledge to be
disabled.
Information about
Transient events is
shown indicating that
they are not
configurable
This causes some of
the alarm report
mechanisms to
extinguish that
particular alarm
indication. These
include Dashboard >
Alarms, Alarm
summary at top of
Web GUI, Physical
alarm connector, front
panel Alarm LED,
and Alarm
information on
front-panel
display.This is just an
acknowledgement of
the alarm, but of
course has no ability
to impact the
underlying condition.
CLI n/a
Front Panel n/a