098-00720-000 Revision D1 – February, 2018 SyncServer 600 Series User’s Guide 293
Appendix B Specifications and Factory Defaults
Factory Defaults
Timing
Offset Scaled Log Variance 0x4e5d 0x0 to 0xffff
Time To Live (TTL) 16 1 to 255
Table B-35. Timing > Holdover Configuration Parameters
Description Default Value Value Range
Time Error Limit Computed from
Holdover
Duration default,
result depends
on oscillator type.
0.000100 ms to 100 ms
Holdover Duration 1 day 0.001 days to 200.00 days
Table B-36. Timing > Serial Parameters
Description Default Value Value Range
Output Off Off | NMEA | NENA | Legacy
NMEA Detail All Off Any combination of the following
allowed: ZDA on/off, GGA on/off, GSV
on/off, RMV on/off
NENA Detail DDD… DDD… | WWW … | YYYY …
Table B-34. PTP > PTP Configuration Parameters for Enterprise Profile (Continued)
Description Default Value Value Range