296 SyncServer 600 Series User’s Guide 098-00720-000 Revision D1 – February, 2018
Appendix B Specifications and Factory Defaults
Factory Defaults
Table B-40. Admin > Alarm Relay Parameters
Description Default Value Value Range
Top Selection Off Any Major Alarm |
Any Major or Minor Alarm | Off
System Restart Delay 0 0, 1, 2,..., 60 minutes
Table B-41. Admin > Alarms Parameters
Description Default Value Value Range
Name N/A Cannot be set by user.
See
Table A - 1 for name of each
alarm
State Strictly condition
driven
Green = condition not set or
has been acknowledged
Blue = condition set at Notify
severity (and has not been
user cleared or
acknowledged)
Orange = condition set at
Minor severity (and has not
been user cleared or
acknowledged)
Red = condition set at Major
severity (and has not been
user cleared or
acknowledged)
Gray = this is a transient
alarm
Clear Now not checked
(all rows)
not checked | checked
Auto ACK (s) 0 (all rows) 0, 1, ..., 999, 1000
Severity
See
Table A-1
for default
severity for each
alarm
Notify | Minor | Major
Reporting Delay (s) 0 (all rows) 0, 1, ..., 999, 1000