EasyManua.ls Logo

Microsemi SyncServer S650 - Page 115

Microsemi SyncServer S650
332 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
098-00720-000 Revision D1 – February, 2018 SyncServer 600 Series User’s Guide 115
Chapter 4
Navigation Windows
SyncServer S650 with optional timing I/O module
Capabilities
Make measurements on a 1PPS signal connected to J1 port of either module A
or module B. Measures the rising edge of the signal compared to the
SyncServer system time.
Calculate statistics and display results - current measurement, number of
measurements, maximum, minimum, mean, median, standard deviation, and
RMS
Take measurements and calculate statistics over a user-selected duration from
10 minutes to 24 hours, or continuous. Web interface button to start and stop
measurement. Statistics are only available if measurements are stored locally,
rather than streamed on an Ethernet port or serial port.
Store results locally or either send results to IP address with selected UDP port
number, or to the timing/event serial port. Results are sent once a second with
the UTC time and measurement result.
Example: 2017-10-30,17:57:35,-1.30000000e-07
Download locally stored data to a file in either UTC or GMT format. Results can
only be downloaded if the measurement was stored locally instead of streaming
to serial or Ethernet port.
UTC: Each measurement is on a separate line containing the time and the
measurement with units of seconds. This download output format lists the
time using the TAI timescale and in the UNIX time format, which is the
integer number of seconds since January 1, 1970, 00:00:00.
Example: 1509386292,-1.30000000e-07
GMT: Each measurement is on a separate line containing the date/time
and the measurement with units of seconds. This download output format
lists the time using the UTC timescale in a format of year-month-day,
hours:minutes:seconds..
Example: 2017-10-30,17:57:35,-1.30000000e-07
Microsemi's TimeMonitor Analyzer application can be used to analyze the
results. Either download the results, or capture results to a file from the serial
port or IP port streams.
TimeMonitor Analyzer can load the UTC-format file with "Load Other
Data->Load Single/Dual Column File …"
TimeMonitor Analyzer can load the GMT-format file with "Load Other
Data->Load Date Phase/Freq File …"

Table of Contents

Related product manuals