EasyManua.ls Logo

Microsemi SyncServer S650 - Page 154

Microsemi SyncServer S650
332 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
154 SyncServer 600 Series User’s Guide 098-00720-000 Revision D1 – February, 2018
Chapter 5
SyncServer S6x0 CLI Command Set
HH=hours.
MM=minutes.
SS=seconds.
mmm=milliseconds.
:=colon separator.
Q=time quality character, as shown below
SPACE = Time error is less than time quality flag 1's threshold
. = Time error has exceeded time quality flag 1's threshold
* = Time error has exceeded time quality flag 2's threshold
# = Time error has exceeded time quality flag 3's threshold
? = Time error has exceeded time quality flag 4's threshold, or a
reference source is unavailable
Example:
To prepare Time on Request, enter:
SyncServer> F9
Then, to request the current time, enter SHIFT-T on your keyboard. ("T" does not
appear).
Response:
<SOH>128:20:30:04.357*<CR><LF>
To exit F9, press Ctrl-C on your keyboard.