098-00720-000 Revision D1 – February, 2018 SyncServer 600 Series User’s Guide 193
Chapter 6 Provisioning
Provisioning Inputs with Manual Entry Controls
IRIG 1344 or
C37.118
No UTC offset
from TAI
PTP:
can't set TAI
timescale
can't set
UTCoffsetValid
flag
Manually set:
utc offset
As a practical
matter, the pending
leap is only for one
minute, so this may
not be useful for
some applications -
in which case
manual use of
pending leap can
help.
NTP
No UTC
offset from
TAI
PTP:
can't set TAI
timescale
can't set
UTCoffsetValid
flag
Manually set:
utc offset
GNSS
without GPS
in the
constellation
configuration
No UTC
offset from
TAI
No Pending
leap
PTP:
can't set TAI
timescale
can't set
UTCoffsetValid
flag
can't indicated
pending leap
NTP:
can't indicate
pending leap
IRIG1344/C37.118:
can't indicate
pending leap
Manually set:
utc offset
Table 6-10. Situations where use of manual time-information can allow for full capability on outputs (Continued)
Input Time
Reference
Information
not provided
by this timing
reference
category
Impact to outputs
if not manually
supplied (or
provided by other
qualified input)
Remedy
Notes

Table of Contents