098-00720-000 Revision D1 – February, 2018 SyncServer 600 Series User’s Guide 265
Appendix A System Messages
System Notification Messages
Excessive
Frequency
Adjustment
174 Major No Excessive frequency
adjustment
Excessive frequency
adjustment cleared
n/a
Input power not
present
175 Minor No No power detected on
[AC1 | AC2 | DC1 | DC2]
No power detected on
[AC1 | AC2 | DC1 | DC2]
cleared
Connect other power
input to AC power
(if dual power version)
Verify backup supply is
operational
n/a
Full system
configuration
occurred
176 Notify Yes Reserved - event will
never be reported
Reserved - event will
never be reported
Configuration
Change
177 Notify Yes Configuration changed
n/a
No action required.
n/a
LPN oscillator
unlock
179 Major No LPN oscillator unlock
LPN oscillator unlock
cleared
If alarm persists,
power-cycle
Call support if it
persists after
power-cycle
No action required
Manual Time Entry
Mode Enabled
180 Minor No Entered Manual Time
Entry Mode
Transitioned out of
Manual Time Entry Mode
No action required
LPN oscillator lock
state changed
181 Notify No LPN Oscillator lock status
changed to xx
LPN Oscillator lock status
changed to xx cleared
No action required
No action required
Table A-1. System Notification Messages (Continued)
Description
Event
ID
Msg
Level
Trans-
itory
MsgText Corrective Action