(1) When connecting with an external device which does not have clock function.
If set to [Adjust] or [Broadcast] for [Clock setting] while the GOT is connected with
external devices (PLC or microcomputers) which do not have clock function, the
clock data will not be adjusted.
Refer to the following for the list of PLC installed with clock function.
GT Designer2 Version Screen Design Manual
(Section 2.4.3 PLC CPUs with clock function)
(2) Clock setting and battery
If [Broadcast] or [None] is selected for [Clock setting], the battery status of the
GOT is required to be normal.
Refer to "GOT internal battery voltage status" to check the battery status.
(3) Operation setting by GT Designer2
Carry out the setting of clock setting in [GOT set up] in [System Environment] of
GT Designer2.
To change a part of the setting after downloading the project data, change the
setting at the display setting of GOT.
GT Designer2 Version
Screen Design Manual
(Section 3.8 Setting of the GOT display and operation (GOT setup))